Lvquan Technology Logo
Equipment Catalog

Edible Fungi Climate Control

Professional temperature and humidity solutions tailored for fungi cultivation projects.
10 Sub-categories
Fungi House Temperature Control Unit

Edible Fungi Dedicated ASHP Air Conditioner LQ-09 (3HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-09
Waterproof RatingIPX4
Power Supply220V 50Hz
Heating (7°C) / Input9.0kW/2.6kW
Heating (-7°C) / Input7.5kW/2.5kW
Heating (-12°C) / Input6.0kW/2.3kW
Heating (-20°C) / Input5.1kW/2.5kW
Heating (-25°C) / Input4.8kW/2.6kW
Cooling (35°C) / Input7.5kW/2.7kW
Air Volume (Indoor)1200m³/h
Max Input / Current3.3kW/13.5A
Applicable Area30-45 sqm
Ambient Temp-30°C~42°C
Fungi Nursery Stage Climate Unit

Edible Fungi Dedicated ASHP Air Conditioner LQ-15 (5HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-15
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input15.0kW/4.7kW
Heating (-7°C) / Input12.5kW/4.1kW
Heating (-12°C) / Input10.0kW/4.3kW
Heating (-20°C) / Input8.5kW/4.3kW
Heating (-25°C) / Input8.0kW/4.4kW
Cooling (35°C) / Input12.5kW/5.3kW
Air Volume (Indoor)2000m³/h
Max Input / Current5.5kW/10.5A
Applicable Area50-75 sqm
Ambient Temp-30°C~42°C
Fruiting Stage Temp-Humidity Unit

Edible Fungi Dedicated ASHP Air Conditioner LQ-24 (8HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-24
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input26.14kW/6.74kW
Heating (-7°C) / Input21.14kW/6.63kW
Heating (-12°C) / Input17.14kW/6.41kW
Heating (-20°C) / Input14.74kW/6.81kW
Heating (-25°C) / Input13.83kW/7.11kW
Cooling (35°C) / Input24.8kW/8.00kW
Air Volume (Indoor)6000m³/h
Max Input / Current8.8kW/16.8A
Applicable Area70-105 sqm
Ambient Temp-30°C~42°C
Agricultural Greenhouse Heat Pump

Edible Fungi Dedicated ASHP Air Conditioner LQ-36 (12HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-36
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input39.0kW/10.8kW
Heating (-7°C) / Input31.2kW/9.84kW
Heating (-12°C) / Input24.0kW/10.0kW
Heating (-20°C) / Input20.4kW/10.4kW
Heating (-25°C) / Input19.2kW/10.6kW
Cooling (35°C) / Input37.2kW/11.7kW
Air Volume (Indoor)7000m³/h
Max Input / Current13.2kW/25.2A
Applicable Area120-170 sqm
Ambient Temp-30°C~42°C
Integrated Climate Recovery Unit

Edible Fungi Dedicated ASHP Air Conditioner LQ-30 (Dual 5HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-30
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input33.0kW/9.0kW
Heating (-7°C) / Input26.0kW/8.2kW
Heating (-12°C) / Input20.0kW/8.4kW
Heating (-20°C) / Input17.0kW/8.7kW
Heating (-25°C) / Input16.0kW/8.8kW
Cooling (35°C) / Input31.0kW/9.8kW
Air Volume (Indoor)6000m³/h
Max Input / Current11kW/21A
Applicable Area100-150 sqm
Ambient Temp-30°C~42°C
Mushroom Factory Fresh-Air Series

Edible Fungi Dedicated ASHP Air Conditioner LQ-45 (Dual 7HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-45
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input43.0kW/13.0kW
Heating (-7°C) / Input37.5kW/12.5kW
Heating (-12°C) / Input30.0kW/12.6kW
Heating (-20°C) / Input25.5kW/12.8kW
Heating (-25°C) / Input24.0kW/13.3kW
Cooling (35°C) / Input45.0kW/13.8kW
Air Volume (Indoor)8000m³/h
Max Input / Current16kW/32A
Applicable Area140-210 sqm
Ambient Temp-30°C~42°C
Cold-Region Fungi Climate Unit

Edible Fungi Dedicated ASHP Air Conditioner LQ-60 (Dual 10HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-60
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input65.0kW/18.8kW
Heating (-7°C) / Input52.0kW/16.4kW
Heating (-12°C) / Input40.0kW/17.2kW
Heating (-20°C) / Input34.0kW/17.6kW
Heating (-25°C) / Input32.0kW/17.8kW
Cooling (35°C) / Input62.0kW/19.2kW
Air Volume (Indoor)14000m³/h
Max Input / Current22kW/44A
Applicable Area200-300 sqm
Ambient Temp-30°C~42°C
Agricultural Inverter Heat Pump

Edible Fungi Dedicated ASHP Air Conditioner LQ-75 (Dual 12HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-75
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input80.0kW/23.5kW
Heating (-7°C) / Input62.5kW/20.5kW
Heating (-12°C) / Input50.0kW/21.5kW
Heating (-20°C) / Input42.5kW/21.8kW
Heating (-25°C) / Input40.0kW/22.2kW
Cooling (35°C) / Input77.0kW/24.0kW
Air Volume (Indoor)16000m³/h
Max Input / Current27kW/54A
Applicable Area240-360 sqm
Ambient Temp-30°C~42°C
Multi-Zone Cultivation Control System

Edible Fungi Dedicated ASHP Air Conditioner LQ-90 (Dual 15HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-90
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input98.0kW/28.2kW
Heating (-7°C) / Input75.0kW/24.6kW
Heating (-12°C) / Input60.0kW/25.5kW
Heating (-20°C) / Input51.0kW/25.8kW
Heating (-25°C) / Input48.0kW/26.6kW
Cooling (35°C) / Input90.0kW/28.8kW
Air Volume (Indoor)18000m³/h
Max Input / Current33kW/66A
Applicable Area300-450 sqm
Ambient Temp-30°C~42°C
OEM/ODM Agricultural Climate Unit

Edible Fungi Dedicated ASHP Air Conditioner LQ-120 (Dual 20HP)

Constant Temperature, Humidity, and Oxygen | Fully Automatic Operation

Technical Parameters
ModelLQ-120
Waterproof RatingIPX4
Power Supply380V 3N~50Hz
Heating (7°C) / Input130.0kW/37.6kW
Heating (-7°C) / Input105.0kW/33.8kW
Heating (-12°C) / Input80.00kW/34.4kW
Heating (-20°C) / Input68.00kW/35.2kW
Heating (-25°C) / Input64.00kW/35.6kW
Cooling (35°C) / Input124.0kW/38.4kW
Air Volume (Indoor)20000m³/h
Max Input / Current44kW/88A
Applicable Area400-600 sqm
Ambient Temp-30°C~42°C